Thermostat contols 24V millivolt furnaces and air conditioners.
NOTE: This thermostat is NOT compatible with baseboards or
any 120V or 240V high voltage control system.
THM301A - UPM BRAND - ENGLISH MANUAL
Programmable
Thermostat
THM301A
Zobrazit stránku 0
1 2 3 4 5 6 ... 30 31

Shrnutí obsahu

Strany 1 - Thermostat

Thermostat contols 24V millivolt furnaces and air conditioners.NOTE: This thermostat is NOT compatible with baseboards or any 120V or 240V high voltag

Strany 2 - TABLE OF CONTENTS

10CHOOSING LOCATION FOR THE NEW THERMOSTATThermostat should be mounted:l Approximately 5 ft (1.5m) from floor.l Near or in a frequently used room, pre

Strany 3

11REPLACING OLD THERMOSTATNote: Do not operate the cooling system when outside temperature is below 10°C (50°F) to avoid damaging the compre

Strany 4 - FEATURES

12MOUNTING THE THERMOSTAT BACK-COVERl The back-cover should be mounted horizontally with the terminals on the left side.l Thread the existing wirin

Strany 5

CONNECTING THE WIRES TO THE TERMINALSConnect the previously labeled wires to the corresponding terminals, matching the designations. Use a screwdriver

Strany 6 - COMPATIBILITY CHART

14WIRING DIAGRAM2-wire heating3-wire heating 4-wire heating/cooling

Strany 7 - Installation

15SETTING THE FAN OPERATION JUMPERDepending on your home's heating system, you may need to change the jumper setting for the fan operation. The j

Strany 8 - INSTALLATION GUIDE

16ATTACHING THE THERMOSTAT TO THE BACK-COVER

Strany 9 - - AA SIZE +

17FUNCTION KEY DESCRIPTIONSLCD DISPLAYDISPLAYUPDOWNSET CLOCKPROGRAMHOLDHEAT/OFF/ COOL CONTROLFAN CONTROLRESETCURRENTBACKProgrammable ThermostatDISPLA

Strany 10

18BUTTONS

Strany 11 - REPLACING OLD THERMOSTAT

19LCD DISPLAYSET TIME AND DAYl Press SET CLOCK to start time setting. The time and SET symbol will flash.l Use AHEAD or BACK to set the current

Strany 12 - Mark the locations

TABLE OF CONTENTSFeatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 13 - Terminals

20PROGRAMMINGPROGRAMSThis thermostat is equipped with 5+2 day programming - separate programming for weekdays,and weekends, with four settings per day

Strany 14 - WIRING DIAGRAM

21Below is a Schedule of the Pre-programmed Time and Temperature Settings:HEATING PROGRAM1- Slide the system switch to the HEAT position and press the

Strany 15

22Note: The PROG key can also be used anytime to review all the set programs. To terminate the programming sequence at anytime, press DISPLAY key.Tip:

Strany 16

23COOLING PROGRAMSlide the system switch to the COOL position and repeat the programming as you would for the Heating programs.TEMPORARY OVERRIDETo ch

Strany 17 - FUNCTION KEY DESCRIPTIONS

24CHECK PROGRAMSl The current program is displayed by pressing the current button.l Press PROG anytime to scroll through and check all other programs.

Strany 18

25FAN CONTROL SWITCHl For automatic control of the fan, set the Fan ON/AUTO switch to the AUTO position. In cooling, the fan starts/stops with th

Strany 19 - LCD DISPLAY

26PRE-COMFORT RECOVERYThis thermostat is equipped with a (Pre-Comfort Recovery) system that will activate the heating or cooling in advance of the act

Strany 20 - PROGRAMMING

27CHANGING BATTERIESWhen 1)the battery symbol on the LCD display flashes, or 2) Temperature is in flashing and a beep sound is heard from the u

Strany 21 - HEAT COOL

28RESETIf the thermostat shows an abnormal display or if you want to clear all existing programs, use a pointed object to press the 'R' key.

Strany 22 - Figure 1

29TROUBLESHOOTING GUIDEPROBLEM SOLUTIONBattery symbol ( ) is flashing.Buzzer beeping.Display will not come on.Air-conditioning will not come on

Strany 23 - HOLD FUNCTION

TABLE OF CONTENTSTemporary override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 24 - ROOM TEMPERATURE

30TROUBLESHOOTING GUIDEPROBLEM SOLUTIONThe current temperature is different from the scheduled temperature.- It is common for the setting and the disp

Strany 25 - HEAT/COOL CONTROL SWITCH

31WARRANTYThis product has a two (2) year warranty against defects in workmanship and materials. This product is not guaranteed against wear or breaka

Strany 26 - PRE-COMFORT RECOVERY

FEATURESl Extra Large LCD display with backlightl Real-time clock with selectable 12 or 24 hour display formatl 5+2 Day Programming with 4 programs pe

Strany 27 - CHANGING BATTERIES

THM301Al This thermostat requires two AA size batteries (included) to operate. Ensure the batteries are installed.l Select °C or °F before clock setti

Strany 28

6COMPATIBILITY CHARTGenerally, equipment with low voltage control is compatible with this thermostat. For details on compatibility of your particular

Strany 30

8INSTALLATION GUIDEINTRODUCTIONThis thermostat can replace common residential thermostats and it is designed for use with most electric, oil or gas he

Strany 31 - WARRANTY

9- AA SIZE +- AA SIZE +Two AA size batteries (included)Wire Stripper/Cutter (If necessary, to strip the wires) Level(If necessary, to level the th