Strany 1 - 7 Day Programmable Thermostat

E L I T ETHM7017 Day Programmable ThermostatTOUCHSCREENTECHNOLOGY

Strany 2

TIMEPROGRAM Display73)Select PROGRAM PERIOD P1 - Morning P2 - Day P3 - Evening P4 - Night2)Select any WEEKDAY, the selected day

Strany 3 - Table of Contents

Select PROGRAM tab to display program settings. - HEAT TEMP (displays heating temperature settings / adjust with up or down arrows)

Strany 4 - Programming Guide

Humidifier Control Verify the humidifier is correctly wired to the thermostat. (see installation guide or contact an electrician)Ensure HEAT mod

Strany 5

10Fan Control / Automatic Ventilation Select FAN/AUTO (for automatic control of the fan) In heating mode, the fan is controlled by the heat

Strany 6 - Symbol Key:

This function will maintain a constant temperature until the next program period starts. If the system is in AUTO mode, only the currently active mode

Strany 7

122131HOLD Function This function will maintain a constant temperature indefinitely.Select the HOLD tab (The HOLD symbol will flash to indicate HOL

Strany 8 - SET CLOCK

Pre-comfort RecoveryThis thermostat is equipped with a ‘Pre-comfort Recovery’ system that will activate the heating or cooling in advance of the actua

Strany 9 - HEAT SETPOINT COOL SETPOINT

Changing BatteriesWhen the battery symbol is visible on the LCD screen, it indicates that the batteries are running low andneed to be replaced. H

Strany 10 - PROGRAM Display

Lock Function To prevent accidental tampering of the programs or to clean the unit, select LOCK for 3 seconds.The LOCK symbol will flash to indicate t

Strany 11 - Heating / Cooling Program

16OPTION SETTINGS (Select the OPTION tab and hold for 3 seconds) OPTION NUMBERVALUEThe thermostat has a number of OPTIONS which the user can change. (

Strany 12 - Humidifier Control

Features: Interface s with heating/air co nditioning system s for autom atic temperature con trol Automatic cha nge-ov er for HEATING/COOLIN

Strany 13

171) (oP0) - Daylight Savings Time Daylight savings time “ON” will advance your clock by one hour.Value 0=DST OFF (Default) Value 1=DST ON 1)

Strany 14 - OVERRIDE UNTIL (Hour)

183) (oP2) - LCD Backlight Select the amount of time the LCD light will stay on after a key is selectedValue 0= OFF (Backlight is always off)Value

Strany 15 - HOLD UNTIL (Day)

196) (oP5) - Heat Cycle Rate Choose the furnace heat cycle (the total ON/OFF intervals that the furnace completes in one hour)Value 0= OFF (Cycle ra

Strany 16 - Filter Change

209) (oP8) - System Type (Conventional Furnace)Depending on your home’s heating system, you may need to choose between a conventionalfurnace system

Strany 18 - Backlight

IntroductionThis thermostat can replace common residential thermostats and it is designed for use with most central heating and air conditioning syste

Strany 19 - OPTION NUMBER

System TypeGas - Standing Pilot Gas - Electronic IgnitionGas - Fire BoilerGas - Millivolt SystemOil - Fire BoilerOil - Fire FurnaceElectric FurnaceEle

Strany 20

3 “AA” size batteries (included)Wire Stripper/Cutter (If necessary, to strip the wires) Level(If necessary, to level the thermostat) Masking Tape (To

Strany 21

Choosing a Location for the new ThermostatThermostat should be mounted: Approximately 5’ (1.5 m) from floor. Near or in a frequently used room

Strany 22

Test the system to make sure that your heating and cooling systems are working properly before installation. If either does not work, contact a heatin

Strany 23

Table of ContentsOperation and programming guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Fu

Strany 24 - Installation

27Remove the thermostat backplate and install 3 “AA” size batteries (included).Ensure the batteries are installed in the correct direction.IMPORTANT -

Strany 25 - Installation Guide

Installing the Batteries and Selecting the Display in °C or °F 28Please consult page 27 for guidelines on how it install the 3 “AA” size batteries

Strany 26 - Compatibility

292-WIRE HEATINGWiring Diagrams3-WIRE HEATING GYH2H1RcRhW/ B/OGYH2H1RcRhW/ B/O(OPTIONAL)JUMPERWiring KeyRegular WiringG - Fan outputY - Cool output H1

Strany 27

Wiring Diagrams30Wiring KeyRegular WiringG - Fan outputY - Cool output H1 / H2 - Humidifier controlRc - Common for Cooling and Fan Rh - Common for Hea

Strany 28

31Humidifier Wiring To wire a humidifier, the 2 wires connecting the original humidistat need to be connected to the 2 terminals marked 'H1&apos

Strany 29 - Replacing the Old Thermostat

Connecting the Wires to the Terminals Connect the previously labeled wires to the corresponding terminals, matching the designations. Use a screwdrive

Strany 30 - IMPORTANT - Getting Started

The back cover should be mounted horizontally with the terminals on the top. Thread the existing wiring through the big center hole from the bac

Strany 31

TROUBLESHOOTING GUIDESpecifications:Number of programs: 7 Day with 4 settings per dayTemperature setting range: 5 – 35°C (41 – 95°F)Temperature displa

Strany 32 - Wiring Key

PROBLEM SOLUTIONHeat will not come on but thesymbol is animated.Air conditioning will not come on.Air conditioning will not come on but the sym

Strany 33

PROBLEM SOLUTIONThermostat is set on AUTO mode, but the thermostat does not seem to automatically change-over from HEAT to COOL or vice-versa.While ad

Strany 34 - Humidifier Wiring

1Operation and Programming Guide

Strany 35

37* NOT COMPATIBLE WITH ANY HIGH VOLTAGE 120/240 VOLT CIRCUIT. Limited 5-year Repair WarrantyThis product carries a five (5) year repair warranty agai

Strany 36 - Back cover

TIMEFull Display - (includes all icons - for reference only)2HUMIDITYPROGRAMPERIODSTATUSSYMBOLSSYSTEMMODEFANMODELOCKWEEKDAYSTABSUP OR DOWN

Strany 37 - TROUBLESHOOTING GUIDE

Symbol Key: COOLING - the air conditioning system is in use. HEATING - the furnace or heating system is in use. FAN - the fan is running (FAN sy

Strany 38

CELSIUS DEFAULT: Since Celsius (°C) is the default mode no action is required to use the thermostat in this mode. (°C or °F) It is VERY IMPORTANT that

Strany 39

Set Time and Weekday SET CLOCK5Press the Clock area for 3 seconds.(The clock numbers will begin to flash)Set the time with UP or DOWN arrows. (Scro

Strany 40

Program Heating and CoolingThis thermostat is equipped with 7 DAY PROGRAMMING. Monday + Tuesday + Wednesday+ Thursday + Friday + Saturday + Sunday pro